    Ask Lasest Price
    Brand Name : Radarking
    Model Number : SKZS
    Certification : CE, CCC, ISO9001, ISO14001, ISO4064
    Price : Negotiate
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 6000000 pcs/year
    Delivery Time : 15-20 working days
    • Product Details
    • Company Profile

    DN15 / 20 / 25mm LoRaWAN Smart Water Meter 165 X 85 X 111mm

    DN15/20/25mm LoRaWAN Smart Water Meter for Cold and Hot Water


    Introduction:
    The wireless smart water meter consists of remote based water meter, wireless communication modules and other components. This product can complete the data collection of point-to-point through the gateway with low power consumption, long life and two-way data transmission. It
    provides reliable protection for the accurate collection of real-time data; Wireless water meter uploads data to the gateway everyday automatically, then the gateway uploads data to the network platform automatically; This product is simple in structure, easy to maintain and replace, and connect with no cables. So, it is easy to install.


    Specification:

    1. Operating environment:

    Water temperature: 0.1℃~30℃

    Protection grade: IP68

    2. Operation water pressure: 0.03MPa~1.0MPa

    3. Pressure loss: ≤0.1MPa

    4. Main Parameters:

    Power ConsumptionStatic current consumption (wireless module doesn’t include counting sensor)≤10µA
    Wireless current receiving power consumption≤18mA
    Wireless current emission power consumptionAbout 120mA

    Wireless

    Performance

    Parameter


    RF center frequency433MHz
    ModulationLORA
    Frequency bandwidth125KHz,250KHz can be optional
    RF power20dbm(100mW) (Typical)
    Transmission rate0.25-50kbps (LoRaWAN)
    Receiver sensitivity-143dBm @SF12/BW 125KHz
    Power supply3.6V lithium batteryMore than 10 years
    Sampling MethodHall sensor, double pulsePointer sampling at 0.01, addend when positive rotation, subtrahend when inverse rotation.

    Specifications:

    Nominal Size

    DN

    mm

    In-Line
    152025
    Maximum flow rateQ4m3/h3.1255.07.875
    Ratio “R”Q3/Q1808080
    Permanent l flow rateQ33

    m3/h

    2.54.06.3
    Transitional flow rateQ220.050.080.126
    Minimum flow rateQ110.0310.050.0787
    Minimum reading

    m3

    0.0005
    Maximum reading99999

    Maximum Permission Error (MPE)
    Q1≦Q≦,Q2 MPE =+ 5% Q2≦Q≦Q4, MPE= + 2% (For hot water metering, MPE=+ 3%)


    Dimensions and diagram


    Nominal sizeLengthWidthHeightThread
    mmD
    15165101124G3/4B
    20195101124G1B
    25225101124

    G5/4B


    Allowable Maximum Error:
    From the minimum flow to the low zone that does not include the demarcation flow: ±5%;
    From the demarcation flow to the high zone including the overload flow: ±2%. 2.8 Communication Distance: City transmission distance: About 2km
    The number of floors crossed: About 15 floors
    Power Supply: The gateway needs an external 220V power supply; All prepaid costs are stored in the meter reading system. Based on the collected data of water consumption, it is determined whether the user owes fees.


    Communication Introduction:
    LoRaWAN is a set of communication protocols and system architectures designed for LoRa long-distance communication networks. When the module is powered on, it automatically sends a join packet. If no reply from the gateway to the network, the join packet will be sent in intervals. After the module receives the network access permission message by the gateway, it pushes a packet of heartbeat data; Since then, it starts timing. Actively push a pack of heartbeat data at intervals of 6 hours. The data upload mechanism can be timed or quantitative or both, and can also be customized on demand.

    Device uploads packets

    NameDataInstruction
    LeadingFEFEFEFE
    Frame initiator68H
    AddressA5 A4 A3 A2 A1 A0Low byte first when sending
    Frame initiator68H
    Control code91H
    Length0CH
    Data identification00004200Low byte first when sending
    Data (Note 1)XXXXXXXXLow byte first when sending
    Status word (Note 2)XXXXLow byte first when sending
    Battery voltageXX15.37×xxH=xxxxxmV
    Reserved bytesXX
    ChecksumCS
    Terminal code16H

    Note1: The data format is defined as follows:

    Data FormatCode SystemUnitRemarks
    Accumulated Water Meter ReadingXXXXXXXXBCDTons

    Cumulative water consumption

    The decimal place defaults to 2 bits of data. The format is: XXXXXX.XX

    Note2: Status word is defined as follows:

    ST0D7D6D5D4D3D2D1D0
    DefinitionMandatory stateStrong magnetic interferenceOverdraft statusAlarm statusVoltageValve status
    InstructionReserved

    0:no mandatory

    1: Forced

    0: normal

    1: Overdraft

    0: normal

    1: Overdraft

    0: normal

    1: alarm

    0: normal

    1:Under voltage


    00: open

    01: Off

    11: Abnormal

    ST1D7D6D5D4D3D2D1
    Definition
    InstructionReservedReservedReservedReserved

    Assembly:

    1.The water meter should be installed in a position where there is clean and dry and no direct sunshine or pollution or drowning.
    2.The water meter should be installed horizontally, and the LCD should be upward.
    3.Water flow must go with the same direction as indicated on the body of the water meter.
    4.When assemble, the valve in front of water meter should be closed.
    5.When assemble, the water meter should be covered to prevent from damage.
    6.The water meter should be connected to the couplings first, and not directly to the water pipe. Extra parts include couplings and nuts.


    Installation and Attentions:
    The installation and use of water meters shall comply with the relevant provisions of Chapter 6 of Standard GB/T778.2-2007 and Article 6.3 of JJG162-2009.

    1. The water meter to be purchased should be based on the flow rate often used in the pipeline, and it should be close to the usual flow rate of the water meter.

    2. Before installing the water meter, foreign matter and contamination in the pipe should be removed.

    3. The installation environment should be suitable, anti- freeze, anti-pollution, waterproof, anti-magnetic and prevent mechanical damage. Water meters should be easy to read, install, maintain, and disassemble.

    4. The water meter should be installed horizontally. The arrows on the case should point in the same direction as the water flow in the pipe. The pipes connected to both ends of the water meter should be installed on the same axis to prevent the water meter and accessories from being damaged.

    5. A stop cock or valve can be installed upstream of the water meter