    Brand Name : Radarking
    Model Number : DTS150
    Certification : IEC62053-21; IEC62052-11; IEC62053-23;
    Price : Negotiate
    Payment Terms : Western Union, T/T, L/C, MoneyGram
    Supply Ability : 5000000 pcs per year
    Delivery Time : 35days
    • Product Details
    • Company Profile

    Light Weight Three Phase Electric Meter With Active / Reactive Energy Measurement

    LCD Display Three Phase Electric Meters with Active & Reactive Energy Measurement


    1. INTRODUCTION:


    Three-phase Active&Reactive Energy Meter adopts the advanced special energy measuring chips and the multi-rate technology, using the date sampling and SMT technology. The product is designed and produced according to the practical situation of the dweller. All the elements inside the meter have the feature of long-life, high-reliance.


    2. MAIN FEATURES:

    Energy Measurement


    Total and time-sharing forward active & reactiveenergy measurement
    Total and time-sharing reverse active & reactiveenergy measurement
    Total forward & reverse apparent energy measurement
    Save last one to sixteen months energy data

    Max. Demand Measurement
    Measure total and time-sharing forward active &reactive maximum demand and time of occurred
    Measure total and time-sharing reverse active &reactive maximum demand and time of occurred
    Measure total forward & reverse apparent maximumdemand and time of occurred

    Real Time Measurement
    Real-time measurement of the phase voltage, current,total active power, reactive power, apparent power, total power factor, powergrid frequency

    TOU
    4tariffs, 100holidays, 14season‐tables, 8time zone‐tables, each table onmaximum 14 time zones

    Optical port interface
    Support IEC62056-21protocol

    RS-485 serial interface
    Communication standards DL/T645-2007, 2400bps forcommunication
    SupportIEC62056(DLMS/COSEM) protocol

    LCD display
    Number of digits value field Up to 8
    Digit size 6x14.5mm

    3. TECHNICAL SPECIFICATION:

    Comprising Table of Model And Impulse Constant (the specification constant value is subject to the nameplate)


    Model

    Reference Voltage

    (V)

    Reference Current

    (A)

    Impulse Constant

    (imp/kWh)

    DTS1503×230V/400V3×5400

    Accuracy Class: Class 0.5

    Rated Frequency: 50Hz

    Starting Current: ≤0.005Ib

    Creeping: Anti-creeping design

    Dimension: 245mm×150mm×78mm

    Weight: 1.5kg

    Lifetime: ≥10 years


    Electrical Parameters


    Normal Operating Voltage3×230V/400V
    Limit Operating Voltage1.2Un

    Voltage Circuit Consumption


    ≤0.5W*3

    Current Circuit Consumption


    <2VA*3

    Climate Conditions

    Normal Operating Temperature-35~+80 ℃
    Limited Operating Temperature-40~+85℃
    Storage And Transportation Temperature-40~+85℃
    Storage And Operating Humidity≤85%H

    4. INSTALLATION AND CONNECTION:

    1. The meter shall be installed in the dry area with good ventilation condition to ensure safety and reliability during installation and operation. If the meter shall be installed in the area with dirty and easily gets damaged, the metering box should be configured to protect meter against the dirty environments.

    2. The dimension of meter is as below: the holes should be digged ahead accord with the size and the meter bottom should be fixed on the strong, fire-proof subjects.




    Safety precautions:
    * Use only isolated tools.
    * Place the meter only in dry surroundings.
    * Make sure the used wires are suitable for the max current the meter can measure.
    * Make sure the AC wires are installed correctly before activating the current/voltage.
    * Do not touch the meter connecting clamps directly with your bare hands, with metal, blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage.
    * Make sure the protection cover is placed after installation and has been sealed.
    * Installation, maintenance and repair should only be done by a certified electrician.
    * Never break the seals or open the front cover as this might influence the functionality of the meter.
    * Do not through, drop, kick or other physical violence to the meter as there are high precision components inside that will break or make the meter measure inaccurate.
    * Do not mount the meter in area's with harm gas, dust, mildew or insects or on unstable surfaces.